Sammi Aoke's small electrode humidifier not only has high humidification efficiency, good steam quality, beautiful appearance design, and almost no sound when the humidifier is running, but also pays attention to the best combination of function and economy. Small electrode humidifiers are often used in conjunction with constant temperature and humidity air conditioners, fresh air units, purification air conditioners, combined air conditioner boxes, etc. Just use ordinary tap water, there are no special requirements for water quality, the humidification speed is fast, it adopts the electrode principle, and the working process is safe and reliable.
Applications of small electrode humidifiers
Electrode humidifiers are used in the electronics industry. At present, domestic electronics factories are becoming more and more strict. In order to ensure the factory quality of products, users must strictly control the temperature and humidity of the production plants. Control, especially humidity, if it is too dry, static electricity will easily be generated in the factory, causing damage to the integrated circuits (note tests have shown that when the relative humidity is , the electrostatic voltage in the factory is , and when the relative humidity is low, static electricity is easily generated in the factory Voltage In addition, too dry air will also cause dust to fly in the air, induce respiratory diseases, affect the physical and mental health of workers, and reduce work efficiency! Generally speaking, the temperature of electronic factories is controlled at around ℃
and the relative humidity is controlled at ~ In this environment, people feel comfortable and static electricity disappears. For example, semiconductor component factories, testing factories, etc. are inseparable from humidification. Choose an electrode humidifier according to your needs.
Use Features of Micro Electrode Humidifier
Clean humidification is small in size, compact in installation, saves floor space, and can be installed at will. High humidification efficiency, good steam quality, beautiful appearance design, almost no sound when the humidifier is running, and at the same time Pay attention to the best combination of function and economy. The control methods are diversified, switching volume control and proportional volume adjustment control are optional. General tap water can be used. There are no special requirements for water quality. It has significant advantages such as fast humidification speed. It adopts the electrode principle to work The process is safe and reliable, and dry burning will not occur. The unique automatic cleaning function ensures long-term stable operation of the humidifier and low maintenance.
Small
Introduction to electrode humidifier
Small electrode humidifier It is also the same as the principle of steam humidification. When tap water enters the electrode humidification tank, the water level gradually rises until the water level overflows the electrode in the humidification tank. The electrode will form a current loop through the water, and the water will be heated and boiled into water vapor by means of the movement of ions in the water. , generate clean steam. The electrode humidifier controls the output of steam by controlling the water level and conductivity in the humidification tank, thereby achieving the purpose of humidifying the air. This series of humidifiers is suitable for household central air-conditioning fan coil units Fresh air ventilators and constant temperature and humidity equipment, etc. can be installed on the side of the fan coil, or on the side of the air conditioning duct or the air duct of the ventilator. The steam spray rod can be installed on the wall of the air duct. Achieve direct humidification of the air duct or fan coil.
Installation of small electrode humidifier
To install the humidifier host, first determine the installation position of the host, whether to use wall-mounted installation or bracket installation. Use wall-mounted installation , use the mounting holes on the rear panel of the host to directly fix it in place with bolts. The bolts must be tightened and installed with a bracket. The user uses angle steel to make a bracket based on the dimensions of the ordered host and the height determined by the specific conditions on site, and places the host on it. Made The bracket must be firm and reliable, and not interfere with all the pipelines and wires connected to the host. No matter which fixing method is adopted, the host must be adjusted horizontally. When installing the humidifier, it must be installed by a person who specializes in electrical installation engineering and has heating skills. Installed by professionals with extensive engineering installation experience. In order to facilitate future humidifier maintenance and repair work, it is recommended to leave enough space when installing the humidifier. When installing the water inlet pipe, make sure that the interface between the water inlet hose and the humidifier water inlet solenoid valve is tightened to avoid leakage, and the water inlet hose is naturally bent to ensure smooth water inlet. Since there is no pressure for drainage, use a hose clamp and the humidifier drainage solenoid valve at one end. The outlet is reliably connected, and the other end is directed to the nearest drainage floor drain. When installing the steam spray rod, use a hose clamp to connect one end of the steam hose to the steam outlet of the humidifier host and the other end to the steam spray rod, and tighten the hose clamp screws to ensure there is no steam leakage. Drill holes at the determined position according to the actual outer diameter of the spray rod, insert the spray rod, and secure it reliably with bolts. The steam exhaust port of the spray rod should face upward.
Small electrode humidifier, atomizing humidifier